Product Overview
HM-QT1 is a handheld fluorometer for fluorescence-based nucleic acid and protein concentration measurement. It measures one sample at a time with dual-color optics and a 5-inch touchscreen. Sample input is 1–20 μL, used with the appropriate fluorescence assay reagents. Use it to assess nucleic acid input for sequencing library preparation and concentration checks in PCR research workflows.
Key Features
- Fluorescence-based quantification with high-efficiency LED excitation and a SiPMT detector.
- Micro-volume sample input of 1–20 μL.
- Five-decade dynamic range and two-point calibration.
- Open reagent platform compatible with suitable Qubit® series quantification kits.
- Integrated 5-inch touchscreen for selecting assays and reviewing results.
Applications
Use fluorescence assays to quantify sample input during NGS library preparation, check DNA concentration before PCR research, and assess low-concentration nucleic acids or proteins after extraction. The integrated touchscreen supports routine bench and portable laboratory workflows. Assay selection must match the optical configuration and reagent kit; microRNA and general RNA assay coverage differ by model.
Technical Specifications
| Parameter | Specification |
|---|---|
| Model | HM-QT1 |
| Sample input | 1–20 μL |
| Sample throughput | 1 |
| Sample container | 0.5 mL clear PCR tube |
| Detection time | ≤5 s per sample |
| Fluorescence channels | 2 |
| Excitation wavelengths | Blue 460–480 nm; red 630–650 nm |
| Emission wavelengths | Green 500–535 nm; red 670–710 nm |
| Light source | High-efficiency LED |
| Detector | SiPMT |
| Sensitivity | dsDNA 0.01 ng/μL |
| Assays | dsDNA, ssDNA, RNA, microRNA and protein with the corresponding assay reagents |
| Dynamic range | 5 decades |
| Calibration | 2-point calibration |
| Display / control | 5-inch touchscreen |
| Power supply | DC 5 V, 2 A |
| Operating environment | 15–30°C; relative humidity <75%; indoor use |
| Dimensions | 110 × 230 × 45.5 mm |
| Weight | 0.5 kg |
Assay Selection
Use the corresponding reagent kit and standards for the selected DNA, RNA or protein assay.
Related Models
| Parameter | Specification |
|---|---|
| HM-QT1 | Single sample; dual-color handheld instrument; 0.5 mL tube |
| HM-QT8 | Eight samples; single-color handheld instrument; assay configuration selected for DNA/protein or microRNA |
| HM-QT8-X2 | Eight samples; dual-color handheld instrument for DNA, RNA and protein assays |
| HM-QT8M | Eight-sample single-color module for workstation integration |
| HM-QT96M | Dual-color module; up to 96 samples; 45 seconds per plate |
Operation and Support
Prepare the sample with the selected assay reagent, perform the required calibration, and load the specified tube or microplate. Read the concentration using the integrated touchscreen. The stated sample input is the sample aliquot used for assay preparation.